Sprinkler water

Sprinkler Minimax MX3 SP K80

The model MX3 SP Screen Sprinkler with a flat cover, K-factor of 80 is a Quick Response Sprinkler with standard irrigation area and glass bulb of 3 mm.
The model MX3 SP Sprinkler is designated for down-deflector installation. The Spray Nozzle MX3 SP is designed for use in commercial buildings with a low, average and high fire load such as banks, hotels, malls, office centers, warehouses, wood processing and chemical plants etc.

International Certificates: VdS, GL, CE, Ministry of Emergency Situations of Ukraine.

TECHNICAL DOCUMENTATION:

MX3_SP_description
Sprinkler21_irrigantion map
Sprinkler21_installation guidelines

Sprinkler Minimax MX3 SU K80

The model MX3 SU Screen Sprinkler with a concave cover, K-factor of 80 is a Quick Response Sprinkler with standard irrigation area and glass bulb of 3 mm.
The model MX3 SU Sprinkler is designated for up-deflector installation. The Spray Nozzle MX3 SU is designed for use in commercial buildings with a low, average and high fire load such as banks, hotels, malls, office centers, warehouses, wood processing and chemical plants etc.

International Certificates: VdS, GL, CE, RUS, GOST-R, Ministry of Emergency Situations of Ukraine.

TECHNICAL DOCUMENTATION:

MX3_SU_description
Sprinkler21_irrigantion map
Sprinkler21_installation guidelines

Sprinkler Minimax MX5 SP K80

The model MX5 SP Screen Sprinkler with a flat cover, K-factor of 80 is a Standard Response Sprinkler with standard irrigation area and glass bulb of 5 mm.
The model MX5 SP Sprinkler is designated for down-deflector installation. The Spray Nozzle MX5 SP is designed for use in commercial buildings with a low, average and high fire load such as banks, hotels, malls, office centers, warehouses, wood processing and chemical plants etc.
The semicountersunk sprinkler version with a flat cover series 21 MX5 SP is designated for use in the buildings with suspended ceilings. The two-section floating box is used enabling to carry out the sunk setting operation up to 12,5 mm (1/2). Such setting enables to cut the pipeline branch to the sprinkler more precisely.

International Certificates: VdS, GL, CE, Ministry of Emergency Situations of Ukraine.

TECHNICAL DOCUMENTATION:

MX5_SP_description
Sprinkler21_irrigantion map
Sprinkler21_installation guidelines

Sprinkler Minimax MX5 SU K80

The model MX5 SU Screen Sprinkler with a concave cover, K-factor of 80 is a Standard Response Sprinkler with standard irrigation area and glass bulb of 5 mm.
The model MX5 SU Sprinkler is designated for the up-deflector installation. The Spray Nozzle MX5 SU is designed for use in the commercial buildings with a low, average and high fire load such as banks, hotels, malls, office centers, warehouses, wood processing and chemical plants etc. The glass bulb contains a heat responsive liquid. When the temperature reaches the rated indicator, the liquid expands shattering the bulb activating the sprinkler and waterway.

International Certificates: VdS, GL, CE, RUS, GOST-R, Ministry of Emergency Situations of Ukraine.

TECHNICAL DOCUMENTATION:

MX5_SU_description
Sprinkler21_irrigantion map
Sprinkler21_installation chart

Sprinkler Minimax MX3-WWH K80

The model MX3-WWH Horizontal Wall-Mounted Quick Response Sprinkler (glass bulb of 3 mm) with K-Factor of 80. The model MX3-WWH Horizontal Spray Nozzle is designed for installation alongside the wall or alongside the beam right under the ceiling. The model WWH Spray Nozzle is usually installed instead of the sprinklers with concave or flat cover on the ground of aesthetic characteristics or if it impossible due to the building construction or it is undesirable to lay the pipelines along the ceiling. The Horizontal Wall-Mounted Sprinklers should be installed horizontally so that average waterway is perpendicular to the wall and parallel to the stream.
The glass bulb contains a heat responsive liquid. When the temperature reaches the rated indicator, the liquid expands shattering the bulb activating the sprinkler and waterway.

Certificates: Ministry of Emergency Situations of Ukraine VdS CEA 4001 regarding sprinkler systems

TECHNICAL DOCUMENTATION:

MX3-WWH_description + irrigation_map

Sprinkler Victaulic V2710 Horizontal K80

The model V2710 with K 5,6 (K=80) Standard Horizontal Wall-Mounted Sprinkler Nozzle
The model V2710 Horizontal Wall-Mounted Standard and Quick Response Spray Nozzle is designated for use in the heat-sink fire suppression systems.
It can be used for standard and hidden installation. The horizontal spray nozzle is designed for the installation alongside the wall or alongside the beam right under the ceiling. The model V2710 spray nozzle is usually installed instead of the sprinklers with concave or flat cover on the ground of aesthetic characteristics or if it impossible due to the building construction or it is undesirable to lay the pipelines along the ceiling. The Horizontal Wall-Mounted Sprinkler is used for standard or hidden installation.

Certificates: UL, ULC, FM, LPCB, VNIPO, Ministry of Emergency Situations of Ukraine.

TECHNICAL DOCUMENTATION:

Description and Irrigation Map V2710
Sprinkler Installation Guidelines V2710
Certificate V2710

Sprinkler Victaulic V2725 Multi-Operated K80

The Model V2725 Standard Quick Response Spray Nozzle is offered in various temperature variants and with various coatings in accordance with structural requirements. The model V27 Sprinkler is designated for use with a heat-sink and dry pipe fire suppression systems and its installation can be vertical or pendent.

Certificates: UL, ULC, FM, LPCB, VdS, CCC, VNIPO, Ministry of Emergency Situations of Ukraine.

TECHNICAL DOCUMENTATION:

Description + Irrigation Map_V27
Certificate_foam + water V27
Sprinkler Installation Guidelines
Technical Description V2725

Sprinkler Victaulic V2703 UP K80

The model V2703 Standard Quick Response Spray Nozzle is offered in various temperature variants and with various coatings in accordance with structural requirements. The model V2703 Sprinkler is designated for use with a heat-sink and dry pipe fire suppression systems and can be installed vertically only.

TECHNICAL DOCUMENTATION:

Sprinkler Installation Chart
Technical Description
Certificate

Sprinkler Victaulic V2707 K80

The model V2707 Sprinkler with a K of 5,6 (K=80)
The Model V2707 Standard Quick Response Spray Nozzle is offered in various temperature variants and with various coatings in accordance with structural requirements. The Model V2707 Sprinkler is designated for use with a heat-sink and dry pipe fire suppression systems and its installation can be pendent only. It is certified for the water suppression. The given sprinkler range is designed for use in the fire suppression systems of the buildings and constructions such as banks, hotels, shopping malls, office centers, storages, parking areas, factories, oil refineries, chemical plants etc.

TECHNICAL DOCUMENTATION:

Sprinkler Installation Guidelines
Technical Description V2707
Certificate V2707

Sprinkler Victaulic V2708 QR K80

The model V2708 Improved Quick Response Spray Nozzle is offered in various temperature variants and with various coatings in accordance with structural requirements. The model V2708 Sprinkler is designated for use with a heat-sink and dry pipe fire suppression systems and its installation can be pendent only.

International Certificates: VdS, GL, CE, Ministry of Emergency Situations of Ukraine.